<<<<<<<<<<<<<<>>>>>>>>>>>>>> ***************************************************************** ***************************************************************** 5/22/2019 Vitals Desktop 3.5.5 Fixes > Do not change GPS info in Valves table. GPS info was modified if some other fields were changed. > Added handling of cases when ValveId is not the 1st field in Valves table. ValveId was assumed to be the 1st field in Valves table. In preview Windows, the 1st field was grabbed and taken as ValveId without checking but some customers may have changed field orders. > Fixed runtime error 53 (“File Not Found”). Vitals Mobile 3.5.5 Fixes > Changed Diagnostic to show transduce zero torque error message for ERV machines only. > Changed torque chart file name to read only. This fixed runtime error 53 (“File Not Found”) in Vitals Desktop. 2/19/18 Vitals Desktop 3.5.4 Fixes > Process torque files under Data as well as in root directory. > Fixed the issue of data transfer if customized fields were added to data base. Vitals Mobile 3.5.4 Fixes > Fixed the issue of missing torque files during data transfer with Vitals Desktop v.3.3.1 or older. Moved torque file folder to under Data. > Fixed the issue of “COM0” not showing up in the available ports list. > Removed system.Drawing.dll which is not needed for HC100 and Trimble Reconn. > Updated copyright year to 2018. 11/29/17 Vitals Desktop 3.5.2 Fixes > Downloaded executable file for Vitals update was added an extra byte. > Signed Vitals_3.5.2_Setup.exe with EV code signing certificate. > Fixed data importing issue with Desktop 3.5.0 where only two torque charts can be imported into Vitals Desktop. Vitals Mobile 3.5.2 Fixes > Added data port back. User can setup data port by editing Settings.txt. 8/23/2017 Vitals Desktop 3.5.0 New Features --------------------------------- > Added a Data Import window in the Data Transfer process for users to review/edit the activities before they import it to the master database. > Checks for updates automatically. > Re-organized the main menu buttons and added new ones. > User now has to exit out of Vitals Mobile before he performs a Data Transfer otherwise a warning message will be shown. > Updated the format for text files from ANSI to UTF-8. > Check if system has Windows Mobile Device Center (WMDC) installed during setup. If WMDC is not found, it will be installed. > Added deletion of multiple fields in Customize Data Fields windows. User can select multiple fields for deletion by Ctrl plus clicking. Vitals Desktop 3.5.0 Fixes ------------------------ > Fixed issue with data loss during Data Transfer because of conflicting Vitals software versions. Data Transfer now works with ANY Vitals version. > Added tabctl32.ocx to installation package. This fixed “Run-time error ‘339’ Component ‘tabctl32.ocx’ or one of its dependencies not correctly registered: a file is missing or invalid”. > Import optimization for data transfer to reduce time needed. > When user browses activities or valves, double clicking on a valve/activity record and either OK or exit out of it, it’ll jump back to the last valve/activity instead of go back to top of the list. > Fixed issue of activities overlapping in print detail. Vitals Desktop 3.5.0 Known Issues --------------------------------- Vitals Mobile 3.5.0 New Features --------------------------------- > Added counts of days and activities since last data transfer. When they reach predefined limits, Vitals Mobile will remind user to perform data transfer. > Added Brake 1 and Brake 2 radio buttons to hydraulics test in diagnostics. > Added Transducer Zero Torque adjustment message at Diagnostic. > Brake button in diagnostics now changes color and status if the physical button is pressed. > Added Vitals Mobile user notifications. > User now has to exit out of Vitals Mobile before he performs a Data Transfer otherwise a warning message will be shown. > TM machines now continuously turn while holding down the JOG button. Vitals Mobile 3.5.0 Fixes ------------------------- > Fixed issue with data fields not showing up in the activity window due to conflicting Vitals versions. Now they show up properly regardless of Vitals software version. > Fixed torque chart with negative counts of turns. Added a red dot for last valve position. > Improved low torque display. Refer to transducer zero torque adjustment part in Vitals reference manual. > Diagnostics properly connects to machines with firmware 1.02 or higher. > Fixed application crash when pressing buttons during database load. > Fixed application exception when changing or loading valve table with a lot of entries. Vitals mobile can now handle valve table with 50,000 records. If entries is more than 50,000, application will not crash but performance will be degraded. Vitals Mobile 3.5.0 Known Issues --------------------------------- ***************************************************************** ***************************************************************** 8/22/2016 Vitals Desktop 3.4.2 New Features --------------------------------- Vitals Desktop 3.4.2 Fixes ------------------------ > Fixed issue with error message showing up after doing a Data Transfer in both English and Chinese languages. > Fixed issue with error message showing up after clicking Customize Data Fields in Chinese language. Vitals Desktop 3.4.2 Known Issues --------------------------------- > Data loss will occur if Data Transfer is performed with Vitals Mobile 3.4.0 or older. Only Data Transfer Vitals Mobile with equivalent Vitals Desktop version (i.e. Vitals Desktop 3.2.1 with Vitals Mobile 3.2.1 etc.). Vitals Mobile Version Vitals Desktop Version Data Transfer Outcome 3.2.x - 3.4.0 3.4.2 Data Loss 3.4.2 3.2.x - 3.4.0 Data Loss 3.2.x - 3.4.0 3.2.x - 3.4.0 Data OK 3.4.2 3.4.2 Data OK > Vitals Desktop might crash after it finishes installing Vitals Mobile to the controller. This seems to happen only once after a new install. > Vitals Desktop might crash if user clicks outside the torque chart window while it is doing an animation. Vitals Mobile 3.4.2 New Features --------------------------------- Vitals Mobile 3.4.2 Fixes ------------------------- > Fixed issue with fields not displaying data in activity window. Vitals Mobile 3.4.2 Known Issues --------------------------------- > Fields in the activity window will disappear and the controller will no longer save data after data transfer with an older version of Vitals Desktop. Only data transfer with Vitals Desktop 3.4.2 or later. > Diagnostics will not connect to machines that have the firmware 1.02 on the circuit boards. It only connects to firmware 1.01. Update to Vitals Mobile 3.5.0 to fix. ***************************************************************** ***************************************************************** 11/4/2015 Vitals Desktop 3.4.1 New Features --------------------------------- Vitals Desktop 3.4.1 Fixes ------------------------ > Fixed issue with Chinese characters entered on the controller not showing up properly in Vitals Desktop after data transfer. Vitals Desktop 3.4.1 Known Issues --------------------------------- > Vitals Desktop might crash after it finishes installing Vitals Mobile to the controller. This seems to happen only once after a new install. > Vitals Desktop might crash if user clicks outside the torque chart window while it is doing an animation. Vitals Mobile 3.4.1 New Features --------------------------------- Vitals Mobile 3.4.1 Fixes ------------------------- > Removed development log function that was creating a log file which would eventually cause the handheld to run out of memory. The log would intermittently pause the machine during operation. Logging functionality was accidently left ON from Beta testing. > Fixed issue with entering text or numeric characters in the NOTES field when using the Simplified Chinese language. Vitals Mobile 3.4.1 Known Issues --------------------------------- ***************************************************************** ***************************************************************** 06/17/2015 Vitals Desktop 3.4.0 New Features --------------------------------- > When Vitals Desktop starts and it does not open the database, it will alert the user that the database was not found. User can search for the existing database or create a new database. > Latitude and Longitude fields added to the Valves table. The most accurate GPS data should be saved in these fields. Data will not be modified or overwritten by activity GPS data. > Vitals Desktop will always look in the Valves table first for latitude and longitude, ensuring the most accurate GPS data is on the handheld controller. If there is no Latitude or longitude in the valves table, Vitals Desktop will average the latitude and longitude from the activities table and export the averaged data to the handheld controller. Vitals Desktop 3.4.0 Fixes ------------------------ > Vitals desktop would create a new empty database "vitalsdb.vcd" and save it in C:\Program Files\Vitals Desktop\db folder (Default location) if it could not open the database. User is now alerted if the database cannot be opened. Vitals Desktop 3.4.0 Known Issues --------------------------------- > Chinese characters entered on the controller not showing up properly in Vitals Desktop after data transfer. > Vitals Desktop might crash after it finishes installing Vitals Mobile to the controller. This seems to happen only once after a new install. > Vitals Desktop might crash if user clicks outside the torque chart window while it is doing an animation. Vitals Mobile 3.4.0 New Features --------------------------------- > New GPS Search screen added for easy viewing of Valve information like distance, bearing, latitude, longitude and HDOP values. > Added No Activity Link. Clicking on a Valve ID and then OK in the About screen will bring the user to the New activity screen with the valve information filled in. > GPS Search Radius. Filters out valves beyond a distance specified in GPS Search Radius. GPS Search Radius added to the settings screen. Default is set to 50'. > Changed transducer error message to indicate valves may break when faulty transducer reading detected. Transducer Error message will remain in the torque bar until RESET is pressed or until faulty transducer readings are corrected. > GPS COM Port and GPS Baud Rate will be set to COM8 and 115200 respectively by default on all the HC-100 controllers. Vitals Mobile 3.4.0 Fixes ------------------------- > Removed the Data COM Port option in the settings screen. Was causing communication issues when the COM Port was set to COM1. > The Autoconnect feature in the controller screen would take multiple re-tries before connecting. Fixed - connects on the first attempt as long as there is a valid connection. > Vitals was recording GPS Data before entering a Valve ID. Vitals will start recording GPS data to an activity only when the user is in the Activity screen or in the Controller screen. Vitals Mobile 3.4.0 Known Issues --------------------------------- > Cannot enter text or numeric characters in the NOTES field when using the Simplified Chinese language. ***************************************************************** ***************************************************************** 11/13/2014 Vitals Mobile 3.3.1 New Features --------------------------------- > Auto Detect Controller= Detects the COM Port if connected via Cable or Bluetooth. > Auto Detect GPS= Detects External GPS first, then searches for internal GPS. Sets COM Port and Baud Rate. > Custom GPS Name field. > Auto-Connect in the controller screen. > Tap to Connect button to manually try to connect. > Bluetooth connection status is highlighted in blue. > Turns bar in the controller screen. > Turns field in the controller screen. > Transducer Error pop-up message. > Default Torque changed from 200 to 150 lb-ft. > Vitals Diagnostics Vitals Desktop 3.3.1 Fixes ------------------------ > New Valves entered (only applies to silver box) not saving to database. Corrupt database template. Fixed with new database template. > Activities for new valves (only applies to silver box) not saving to database. Corrupt database template. Database template which has been fixed. > Expr1003 and Expr1008 showing up in CloseDir and CrossStreet fields in the Activity Report. Fixed. > Overlapping characters in the Activity Report. Fixed. > Activity Report not displaying all 20 Characters in ValveID field. TRQ Chart resized to fit characters. > Activities from Recon controllers not saving to database. Notes field contained a ?square? character. This square character gets created when user hits the Enter key to skip to next line. This Character was not recognized by Vitals Desktop and it disregarded the Activity altogether. This has being fixed; now the Enter key shows as two parallel lines. > ValveId field was empty for activities saved in Vitals Desktop. Too many characters entered into ValveID field (over20). Fixed by having a limit of 20 characters in Vitals Mobile. Vitals Mobile 3.3.1 Fixes ------------------------- > 1000th Activity not saving. TRQ charts can only go up to 999. It will prompt the user to do a Data Transfer first to the PC before starting another activity. Fixed. > Problems connecting to GPS and Controller. Removed the Lock Settings feature since the auto detect feature was causing problems. Fixed. > Transducer Error false readings on TM7. Decreased ADC range to check. Fixed. > Vary few COM Ports and Baud Rates to select from. Increased COM Ports and Baud Rate options. Fixed. ***************************************************************** ***************************************************************** Vitals Desktop 3.2.1 New Features --------------------------------- > Previous versions' COM port range during Data Transfer for Controller/Data Logger and TMC-DT1 Controller was limited to COM1 through COM9. Range was increased to COM99 for USB to RS232 adapters. > Previous versions' New Database dialog box showed 'Open' button instead of 'Save'. Dialog box was changed from Open Dialog to Save Dialog for creation of new databases. Vitals Mobile 3.2.1 Fixes ------------------------- > GPS device detection caused Vitals Mobile to freeze with spinning wheel only in version 3.2.0. GPS device detection fixed and re-enabled in version 3.2.1. Vitals Desktop 3.2.1 Known Issues --------------------------------- > Activities from Silver Boxes will not save to database after Data Transfer. > Overlapping of characters in the Activity Report. > Expr1003 and Expr1008 showing up in CloseDir and CrossStreet fields in the Activity Report. > If a Valve ID has more than 12 characters, it will get cut off from the Activity Report because of the size of the Torque Chart. > Activities from Recon controllers will not save to database after a Data Transfer if the Notes field of an activity has a ?square? character. This square character gets created when the user hits the Enter key in the keyboard to skip to the line below. This Character will not get recognized by Vitals Desktop and it will disregard the Activity altogether, and therefore not saving it. > ValveId field is empty for activities saved in Vitals Desktop; if the user enters a ValveId (in the Recon Controller) that has more than 20 characters, it will not populate that field once it has being transferred to Vitals Desktop. > Vitals table in MS Access lists Version 3.1.0 when it should be 3.2.1. Vitals Mobile 3.2.1 Known Issues ----------------------- > Vitals Mobile does not saves an activity if the Controller already has 999 activities saved on the controller; this is because you cannot have more than 999 trq charts on the device. > Valve ID field does not have a character limit. > Enter key creates square characters in Notes field. > Lock Settings causes more problems with the Auto Detect feature. > Not many COM Port and Baud Rate options. ***************************************************************** ***************************************************************** Vitals Desktop 3.2.0 New Features ------------------------------- > Multi-language support. > Vitals Desktop will keep track of the current language being used and the language last loaded to Vitals Mobile. When the language changes on Vitals Desktop, or if the Vitals Mobile language file is missing, and a Data Transfer is performed, Vitals Desktop will transfer the currently used language to Vitals Mobile. > There is no need to exit Vitals Mobile to change the language. Simply perform a Data Transfer while using a new language in Vitals Desktop and Vitals Mobile will automatically translate its interface. > New language auto-add. Drop new language file into application path folder and language is automatically included in software. (Certain languages require a change to the Regional Settings --> System Locale to enable special characters) > Option to install Vitals Mobile 3.2 on Recon device or keep current version. > ActiveSync/WMDC auto-detect/install. > Robust system registration for software components used in Vitals. > Message added to make user aware of 5,000 valve upload "limit". > Removed "Refresh" button from valve and activity information grids. Valve/activity information will now automatically refresh as soon as it is changed. > Unit of measurement appears next to torque when creating a new valve. > Option to email Vitals Tech Support from Help menu. Vitals Mobile 3.2.0 New Features ------------------------------ > Multi-language support. > COM port/Bluetooth auto-detect. > Status string displays whether or not there is a cable or Bluetooth connection. > GPS COM port, baud rate, and model auto-detect. > 57600 baud rate added for Hemisphere GPS. > Controller Settings initially locked to enable auto-detection features. > Battery percentage indicator. > GPS coordinates account for different hemispheres on Earth, providing correct GPS coordinates world-wide. > COM port "None" setting removed - unnecessary and causing errors. > Updated TM transducer error message and new ERV transducer error message. > Unit of measurement appears next to torque on controller screen. > Included PocketMAX3 software for advanced Hemisphere GPS configuration. > Upgrade from .NET Compact Framework version 2.0 to version 3.5 to enable use of PocketMAX3 software. Vitals Desktop 3.2.0 Fixes ------------------------ > If a valve has activities associated with it, you can change the ValveID of a single activity associated with that valve, or the valve itself, and the rest of the activities associated with that valve will keep the old ValveID. The ValveID is now bound together between valves and activities - if you change the ValveID of a valve, all activities will update with the new ValveID; you cannot change the ValveID through an activity; you cannot create a new activity without creating a valve first. > Valve count in "Browse Valves"/"Browse Activities" showed "-1/0" when there were no valves in the database. This will now show "0/0". > Print Detail would only print the most recent activity performed on a valve. Print Detail will now show user-selected information for every activity associated with a valve. > Users could not perform Activity Report of custom data fields if there was a space or special character in the name of the field. Users can now print Activity Reports using custom data fields named with spaces and special characters. > Valve Info section in "Browse Valves"/"Browse Activities" caused Vitals program to crash if clicked and there were no valves in the database and the Valve Info section was empty. There is now no effect from clicking in this box. > Vitals program receives error and quits when trying to perform database activity and then trying to set custom color. Fixed. > Vitals program receives error and quits when opening a data transfer session, choosing "Specify Valve Records" radio button, and then trying to view contents of combo boxes. Fixed. > Vitals program tries to open current database in MS Access. If MS Access is not installed this error appears and Vitals quits. > Deleting a field through Customize Data Fields did not delete the field in the MS Access database. Fixed. Vitals 3.2.0 Known Issues ----------------------- > (For foreign languages wishing to see date in a different format) Date format is dependent upon regional settings of Recon device and Windows desktop PC. > Foreign languages Chinese, German, and Japanese require a firmware update to enable special characters. (English firmware update required if firmware has been changed to one of the aforementioned firmwares) > Hemisphere GPS unit is sub-meter AFTER post-processing of collected coordinate information. > Battery power reading/indication of Windows Mobile operating system (produced by Microsoft) is unreliable. Battery percentage indicator in Vitals Mobile reflects battery reading from Windows Mobile operating system.